M/s FATIMA INTERIOR SOLUTION PVT LTD, established in 2001, is a reputable and registered waterproofing company specializing in various waterproofing methods. The company takes pride in its expertise in cement-based waterproofing treatment and chemical treatment, providing effective solutions for waterproofing needs.
The company is an innovator in introducing methods such as “Injection,” “Box & Surface” for underground superstructures, and water-retaining structures of any scale. These methods demonstrate the company’s commitment to staying at the forefront of industry advancements and adopting innovative approaches to waterproofing challenges.
M/s FATIMA INTERIOR SOLUTION PVT LTD is also involved in the manufacturing of “SEAL ROOF,” a waterproofing and damping powder. This product, developed by the company, is utilized in its projects, reflecting a hands-on approach to quality control and assurance.
With its comprehensive waterproofing services and commitment to quality products, M/s FATIMA INTERIOR SOLUTION PVT LTD has established itself as a trusted name in the industry. The company’s dedication to innovation and excellence sets it apart in providing effective solutions for various waterproofing needs.
WATER PROOFING
Waterproofing plays a crucial role in building construction, requiring an understanding of the construction process, structural elements, joints, material chemistry, and design factors. Simply filling visible cracks or applying generic chemicals is inadequate to prevent water ingress into the structure. More comprehensive measures are necessary to ensure effective waterproofing.
WHAT WE DO ?
With a profound association with the construction industry, we have recognized water as the primary cause of structural damage. Our expertise lies in waterproofing, where we employ diverse methods and materials, avoiding a one-size-fits-all approach.
Specializing in treating plain walls, our systems have consistently outperformed others in challenging situations. From basement to rooftop, we cover the entire building, with a particular focus on exterior wall surfaces. Our unique treatment systems ensure long-lasting performance.
As Structural Waterproofing specialists, our services encompass three main areas: executing waterproofing jobs, formulating and trading waterproofing materials, and providing consultation to address waterproofing issues. We follow a systematic, phased operation to carry out waterproofing jobs, studying leakage problems and determining suitable methodologies and materials.
Our formulated chemicals, including M.M. Stone Polymer and Xailexcon, along with products like ‘Crack fill’ fibers, are available to other independent waterproofing contractors. We also engage in trading locally manufactured or imported materials.
For leakage problems, we analyze and recommend suitable methodologies and products, offering supervision if required. Additionally, we provide comprehensive consultation for fixing Asphalt Shingles on Chajjas or canopies.
Our mission is to deliver cost-effective, reliable, and enduring solutions to leakage problems promptly, spreading positive energy in every project we undertake.
SEALROOF PROCESS
While our waterproofing method may be complex, we offer three options to cater to our customer’s needs and budget, varying in specifications. Buildings earmarked for redevelopment in the near future may not require expensive options, especially with the unique design created on dead walls.
It’s crucial to grasp that waterproofing a building cannot be executed in patches or localized areas where leaks are visible. To be effective, it must cover the entire building; otherwise, it becomes a waste of money, time, and a source of frustration.
Typically, the process involves cleaning the surface with a high-pressure water jet, cutting and filling cracks with specialized mortar, covering metal insertions, and coating the entire surface with ‘Xailexcon.’ Subsequently, the surface receives three coats of our specialized composite material made from M.M. Stone Polymer, proprietary chemicals (SK027, DM054), white sand, and cement. The application is done by brush or trowel, with on-site mixing based on specific requirements. The final step involves painting the surface in the desired shade.
Additional work, such as relocating pipes, PCM treatment on damaged RCC members, and re-plastering in patches, may be performed before the main treatment. A unique treatment is applied to large uninterrupted plain surfaces of dead walls exposed to constant thermal variations, preventing easy cracking and ensuring long-lasting performance. Our waterproofing system is particularly effective after major repairs, addressing joints formed during patching-up.
We propose to treat the U/G Structure by our ‘Box Method’ For this we would require 150mm (6′) thick layer of cement concrete (1:3:6) P.C.C. using metal upto No 2 laid even with smooth surface with wooden trowels by the owners on well compacted soil or rubble soling or plain concrete.
The bottom P.C.C. should be laid in such way that it shall project minimum 6′ (150 mm)
Beyond the face of bottom P.C.C. Raft on all sides. On the P.C.C. we shall provide our ‘SEALROOF’ waterproof layer C.M. of 1″ thick on which stone aggregate of nominal size will be embedded at random.
We shall provide Shahabad rough ladi (stone) of about 1 to 2 feet square and of 20 to 25mm thick fixed in C.M. (1:4) above the ladi we shall again provide our “Seal roof” Waterproof layer of 1/2″ to 3/4″ thick. Like this the total thickness of our treatment becomes of 3″ thick. This is then super imposed by the owner with R.C.C. Raft.
After casting of R.C.C. Raft and side walls by the owners, the outer face of the walls are provided with our Shahabad ladi and then grouted with cement slurry, above the ladi we shall provide 1/2″ to 3/4″ thick “Seal roof” waterproof layer, like wise out treatment becomes of about 1 3/4 thick. The outer treatment is carried out up to a height of about one foot above ground level.
The excavated portion of the sides around is then of simultaneously with our work is filled in by the owners with soft earth.
By this method the entire structure is encased by our treatment and the attacking subsoil water will not find an access to it.
IMPORTANT:
As already stated above, the earth filling on the outside wall shall be done by the owners. Simultaneously with the progress of our work on the outer face of the walls.
No injection in any other treatment is given to the walls inside as a part of the above or otherwise.
Expansion joints, in the basement floor and wall are not needed.
SIDE WALL
R.C.C. Side wall.
Shahabad rough ladi fixed in fine cement paste.
Neat cement slurry filled in between R.C.C. wall & Shahabad ladi
Top smooth finish in cement mortar.
FLOORING
P.C.C. (150 mm) thick to be laid by owner.
Stone Aggregate fixed by hand cement mortar (1.5)
Cement mortar (1:4) laid for fixing rough Shahabad ladi
Shahabad ladi fixed in cement mortar.
Top finish in cement mortar (1:4)
R.C.C. Raft slab laid.
Note: Soft earth filling on the outer face shall be done by owner simultaneously with the progress of water proofing work.
In case of existing Basement where no access is available for treating the surface from outside and below. We propose to treat the U/G structure by our “Injection & Surface” Method.
The junction of the bottom raft with the vertical wall is to be opened by us and filled with the vertical wall is to be opened by us and filled with metal aggregate of nominal size along with injection (coupling). In the wall area all construction joints are opened to provide Injections. Injections shall be provided as and where found necessary are Bu us as per site conditions. The injections are filled with cement slurry (grouting).
After the injections are finished with cement grouting. We shall provide a layer of I.P.S. of about 2″ thick on the floor and the vertical wall is covered with out “Seal roof” water proof layer of about 1″ thick like this the structure is waterproofed from inside.
Note: This method is also applicable for Underground tanks. Lift Pits and Overhead water tanks.
The final surface of the floor will be finished smooth in cement color and
that of the Walls with cement / neru finish.
If however. It is desired to provide tilling over our treatment then the
surface of our treatment will be finished in a manner to receive the tiles.
It may please be noted that our treatment should in no manner be
punctured or damaged. If any fixtures are necessary, then they will be
provided on a protective wall, to be provided over our treatment. So that
our treatment is not damaged of tampered with.
In case the floor of the basement is to be subjected to rough and/or heavy
use. Then a Suitable wearing coat on our surface shall be necessary to be
provided by the owners.
In case any existing treatment is present, the same shall be removed by us
to expose The surface of R.C.C. Raft.
The new Bathrooms/Toilets etc. are treated with our “Surface” method which starts directly over the R.C.C. Slab. The internal wall shall be plastered leaving a space of about 600mm (2 feet) from floor level.
Before the commencement of our work all chiseling / cutting in the floor and wall shall be done by the Plumber.
Note:
A. The rates are quoted separately for waterproof plaster as one item and filling the sunken portion as second item. No deduction in the floor and wall area for pans and other fittings and fixture are made in the measurement.
B. In the case of existing toilets etc. the existing treatment including filling in the depression and tilling on the floor and on the walls up to 600mm shall be removed by the plumber/owner and rectify or replace all the defective plumbing etc. before we commence our work.
Note: As soon as waterproof plaster in finished the owner shall provide all provide all pipes & fittings including fixing of W C pan.
In case of existing Basement where no access is available for treating the surface from outside and below. We propose to treat the U/G structure by our “Injection & Surface” Method.
The terrace is treated with our “Surface” method which starts directly over the R.C.C. Slab. The internal parapet or other adjoining walls shall be plastered leaving a space of about 18″ from the slab for our Wata (Golia). The R.C.C. Slab be well cleaned and rain water outlets pipes fitted by the owner before the commencement of our work
1. The R.C.C. Slab shall be well cleaned with water and will be grouted/ flooded with cement slurry. Now we shall fix our “Brick bat” in C.M. with necessary gradient for the easy flow of rain water (the treatment shall then be cured for at least 48 hours).
2. The “Brick Bat” is finally covered with our “Sealroof” waterproof plaster finished with smooth trowels with false marking of 300mm squares or finished rough as desired by the owners/clients. Our treatment is carried along the vertical surface of parapets and other adjoining walls upto a height of about 1 foot in the shape of round Wata. The average thickness of our treatment is about 110mm (41/2″). The thickness at rain water outlet points being 75mm (3″). The maximum slope will be 1″ per 10 feet area.
(A) The surface provided is hard and tough suitable for all normal domestic purposes. It has got better insulation value than the bitumastic.
(B) If however, it is desired to cover our treatment with decorative tiles, marbles etc. then the surface of our treatment will be finished suitable to receive them.
(C) Due to location of rain water pipes being for apart and due to the span being wider than 30′ or 9 meters and the water is required to travel on one side only then the thickness of our treatment increases proportionately to maintain the gradient for the easy flow of rain water.
(D) In the case of existing terrace since our treatment starts directly over the R.C.C. slabs stated above, the existing treatment will have to be completely removed by us to expose the bare surface of the R.C.C. slab. (E)If a garden and/or a lawn in desired to be made over the treatment. It can be suitable for that also at extra charges.
Note: Average thickness of work is 110mmSlope is (1:120) 1 Inch in Every 10 Feet.
The main contractor shall first provide 4″ thick-18″ height brick masonry on the Slab floor ; above which we shall provide 24 Gauge Aluminum sheet with a grove in the center and overlapping on one side the other side shall be up to the edge of Brick masonry. The grove shall be filled with plain paper the same paper shall be pasted with cement paste on the top of Aluminum Sheet above which over average 110mm Brick-bat will be laid after filling he joints of Brick-bar in C.S. mortar, We shall fix wire-mesh on it and finally the top will be finished in smooth cement color with overlapping on both sides of brick masonry. Expansion joints can also be treated by filling the gap with Poly-Sulphate Sealant
it mainly depends upon the procedure & specification given by Client/Architects. In general it is a two component polymer modified cementitious coating. It is an ideal waterproof coating which forms elastomeric membrane capable of excellent adhesion, breathability and is flexible non toxic.
The two components are mix thoroughly to form a uniform paste and is applied on the wet surface with a brush two coats are recommended. After the second coat is applied a protective tacky coating or plaster has to be done in C: M (1:4), the average thickness of our treatment will be 25mm. to 40mm. as required.
BASEMENTS / TANKS / LIFT PITS / Etc
The treatment mainly depends upon the procedure & specification provided by the architect /owner. In general it is a highly alkaline cementitious process which works as crystallization process when applied with brush on concrete surface in slurry form. (2 Coats is recommended).This becomes an integral part of the concrete through crystallization process which seals all cracks and voids. Above this a protective coating of plaster has to be provided. Apart from this we shall also provide nozzles for grouting as and where required as per site condition
DR.FIXIT BLUESEAL AS OPPOSED TO BRICKBAT COBA ENSURES
METHODOLOGY
SURFACE PREPARATION
Clean the surface thoroughly to get rid of all contaminants. Remove all surface imperfection and repair with a polymer modified mortar using Dr. Fixit predicrete URP.
APPLICATION
METHODOLOGY
SURFACE PREPARATION Clean the surface thoroughly to get rid of all contaminants. Remove all surface imperfections and repair with a polymer modified mortar using Dr.Fixit Pridicrete URP. APPLICATIONMETHODOLOGY
SURFACE PREPERATION Clean the surface thoroughly to get rid of all contaminants. Remove all surface imperfection and repair with a polymer modified mortar using Dr.Fixit Pidicrete URP. APPLICATIONAPP MODIFIED BITUMEN BASED TORCH APPLIED MEMBRANE FOR FLAT ROOFS.
METHODOLOGY
SURFACE PREPERATION
Clean the surface thoroughly to get rid of all contaminants. Remove all surface imperfection and repair with a polymer modified mortar using Dr. Fixit pidicrete URP.
APPLICATION
HIGH PERFORMANCE WATERPROOFING COATING FOR ROOFS.
METHODOLOGY
SURFACE PREPERATION
Cut open and clean cracks in the existing screed or brickbat coba systems and repair them with polymer modified mortar modified with Dr. Fixit Pidicrete URP.
APPLICATION
APP MODIFIED BITUMEN BASED TORCH APPLIED MEMBRANE
METHODOLOGY
SURFACE PREPERATION
Clean the surface thoroughly to get rid of all contaminants. Remove all surface imperfection and repair with polymer modified mortar using Dr. Fixit pidicrete URP.
APPLICATION
APP MODIFIED BITUMEN BASED TORCH APPLIED MEMBRANE
METHODOLOGY
SURFACE PREPERATION
Clean the surface thoroughly to get rid contaminant . Remove all surface imperfection and repair with a polymer modified mortar using Dr. Fixit Pidicrete.
APPLICATION
With over 23 years of excellence, M/s FATIMA INTERIOR SOLUTION PVT LTD stands as a symbol of global standards, pioneering the way in Thermal Insulation for Hotels, Commercial Projects, and technology parks that rival the best in the world.
Thermal insulation plays a crucial role in reducing the effects of heat transfer between objects or within the range of radioactive influence. Heat, being the transfer of thermal energy between objects of varying temperatures, requires effective measures to control its flow. This can involve specially engineered methods, processes, and the use of suitable static objects and materials.
In the realm of building construction, insulating materials are quantitatively measured by their insulating capability, often referred to as the R-value. The calculation of these requirements involves considering various factors, including industry standards that have evolved over the years, balancing conflicting goals such as cost, climate, building practices, and comfort standards.
For large industrial applications, heat transfer and layer analysis are performed, while in household situations like appliances and building insulation, achieving air-tightness is crucial to reduce heat transfer due to air leakage, whether forced or natural convection. Once air-tightness is established, selecting the appropriate thickness of the insulating layer is often based on practical rules of thumb, as diminishing returns are observed with each successive doubling of the insulating layer. Certain systems may even have a minimum insulation thickness requirement for noticeable improvements.
Buildings & Hotels:-
The application of thermal insulation in hotel buildings is a crucial aspect of energy efficiency and overall occupant comfort. Maintaining acceptable temperatures through heating and cooling represents a significant portion of global energy consumption. Proper insulation offers several advantages:
Energy Efficiency: Well-insulated hotel buildings are energy-efficient, leading to cost savings for the owner.
Temperature Uniformity: Insulation helps maintain more uniform temperatures throughout the space, reducing temperature gradients both vertically and horizontally. This creates a more comfortable environment for occupants, especially in extreme cold or hot weather.
Minimal Recurring Expense: Unlike heating and cooling equipment, insulation is a permanent solution that does not require regular maintenance, upkeep, or adjustments.
Noise and Vibration Reduction: Many forms of thermal insulation also contribute to reducing noise and vibration from external sources and other rooms within the building, enhancing overall comfort.
In addition to these benefits, pipe insulation is essential for maintaining the temperature of pipes carrying heated or cooled fluids. Window insulation film can be applied for weatherization purposes, reducing thermal radiation in summer and heat loss in winter.
Implementing thermal insulation is a challenging task that requires careful supervision and proper training during installation. It is crucial to select the right materials for the intended purpose, and any mistakes in this process can lead to ineffective insulation. Proper training, often provided by the supplier of insulation materials, is essential for the successful installation of thermal insulation.
M/s FATIMA INTERIOR SOLUTION PVT LTD is proud to be a dealer and partner of Aisladecx AL, a world-class product for thermal insulation. The company has successfully carried out thermal insulation projects, including notable clients like ITC GRAND MARATHA HOTEL, showcasing its commitment to quality and client satisfaction.
BASEMENTS / TANKS / LIFT PITS / Etc.
The treatment mainly depends upon the procedure & specification provided by the
architect /owner. In general it is a highly alkaline cementations process which works as
crystallization process when applied with brush on concrete surface in slurry form. (2
Coats is recommended).This becomes an integral part of the concrete through
crystallization process which seals all cracks and voids. Above this a protective coating of
plaster has to be provided. Apart from this we shall also provide nozzles for grouting as and
where required as per site condition.
Project
1) M/s INS SHIVAJI at Lonavala Bhushi Dam
In INS Shivaji we have done basement Water Proofing job.
2) M/s Progressive Construction Co. Pvt. Ltd.
In Progressive Construction Ltd. we have done basement Water Proofing job.
3) M/s SANJONA Developers (Thane)
In Sanjona Developers we have done basement1 & 2 Water Proofing job.
4) M/s ITC GRAND MARATHA HOTEL
In Sahar Road Andheri- East Mumbai
5) Novotel Hotel (Juhu, Mumbai)
Two years ago In Novotel Hotels we had done basement 2 complete Water Proofing
treatment job at bunker area, Housekeeping area & Laundry area. Also we have done
Shahabad tile fixing job, cement chemical grouting, waterproofing IPS plaster & total
Waterproofing job of Swimming pool of Capacity 4.5 Lakh liter water.